0
hello@avsupply.co.za

Sales and technical enquiries

All Categories
Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
  • Vision TC3 RJ45 module, white plate marked Ethernet with its rear RJ45 socket on a green circuit board
Cable Termination

Vision Cable Termination System V3, RG45 Module – 3446576

R591.20

  • (0)

One Cat 6 network point at a Vision Techconnect 3 (TC3) plate, where the cable behind the wall already ends in an RJ45 plug or patch lead.

  • Shielded RJ45 socket at the front, rated Cat 6
  • RJ45 socket at the rear: a patch lead plugs in, nothing is punched down
  • One space in a TC3 surround
  • 64 x 21 x 40 mm
  • Brand :Vision
  • SKU :VISION-3446576
  • Category :Cable Termination
  • Availability : In Stock

14 in stock

  • Description
  • Specifications
  • Reviews (0)
  • Datasheets

The Vision TC3 RJ45 module (part 3446576) puts one shielded Cat 6 network socket on a Techconnect 3 plate. It is a coupler: a small circuit board behind the front socket joins it to a second RJ45 socket, and the network cable plugs into that second socket. The module takes one space in a TC3 surround and is 40 mm deep.

Where a coupler suits better than punch-down

Use it where a data outlet already exists in the floor box, wall or lectern and the TC3 plate only has to present it to the user, with a short patch lead between the two. Because nothing is terminated on the module, it can later be moved to another plate or swapped without re-making a cable end.

To terminate new Cat 5e or Cat 6 cable at the plate itself, choose the Vision TC3 twin RJ45 module (3446209) instead. It has push-down connectors at the rear and fits two network sockets into the same single space.

Planning the plate around it

A TC3 1-gang surround (3446602) takes this module and one more, for example a TC3 HDMI module (3446573) so a laptop gets a picture and a network point at the same plate. On a solid wall without a recessed box, the surround fixes to the TC3 1-gang surface-mount backbox (3446597), which measures 86 x 86 x 45 mm. Leave space behind the module for the patch lead’s plug and the bend in its cable.

Key specifications of the Vision TC3 RJ45 module

Vision part TC3 RJ45, 3446576
Front 1 x RJ45 socket, shielded
Rear RJ45 socket (coupler, no punch-down)
Cable rating Cat 6
RJ11 phone plugs Fit the socket
Module spaces 1
Size 64 x 21 x 40 mm
Weight 0.03 kg
Colour White

Questions about the Vision TC3 RJ45 module

Do I need a punch-down tool to fit the TC3 RJ45 module?

Not at the plate. Both connections on the module are RJ45 sockets, so fitting it means plugging in a patch lead and fixing the module into its surround. The installed cable still has to be terminated where it ends, on a jack or a patch panel, and that is where the tool comes in.

Is a patch lead included?

No lead is listed with it, and Vision’s datasheet and photos show the module on its own. Order a Cat 6 patch lead long enough to reach from the rear socket to the data outlet or cable end behind the plate.

Can I plug a telephone into it?

Yes. Vision states that the socket accepts RJ11 phone plugs, so an ordinary telephone cord connects at the front. Behind the plate the line also has to arrive on a plug, because the rear connection is a socket, not a terminal.

Will PoE or HDBaseT work through it?

Vision publishes no Power over Ethernet (PoE) or HDBaseT rating for this module. Both normally run on Cat 6 cabling, but the coupler adds a plug-and-socket joint and a patch lead to the link at the outlet. Test a PoE device or an HDBaseT extender through one plate before repeating the layout across a building.

COLORWhite
MATERIALABS Plastic
PRODUCT DIMENSIONS64 x 21 x 40 mm / 2.5" x 0.83" x 1.57"
PRODUCT WEIGHT0.03 kg (0.07 lb)
PACKAGED WEIGHT0.03 kg (0.07 lb)
PACKAGED DIMENSIONS90 x 150 mm/ 3.54" x 5.91"
TC3 RJ45 [EU SAP3446576]

Reviews

There are no reviews yet.

Be the first to review “Vision Cable Termination System V3, RG45 Module – 3446576”
Featured

AV Signal Distribution

From R127.19

AV Signal Distribution
Popular

Screens

From R847.72

Screens
In stock

Projector

From R569.15

Projector
Courier delivery across South Africa
Two to three working days to the main centres
Seven day cooling off, as the ECT Act requires
Commercial audio visual equipment
Email us about any order