A 60 W mono amplifier for one zone of 70 V or 100 V ceiling speakers, with knobs in place of DSP.
Out of stock
The Aten AP106 is a 60 W RMS mono Class D amplifier for 70 V and 100 V distributed speaker lines. It has no 4 Ω or 8 Ω output, so every speaker on it needs a line transformer, and no DSP or network port: volume, bass and treble are knobs on the front. Up to 60 W of speaker taps fit on its single output, for example two Aten AS106 speakers on 30 W.
A switch beside the 2-pin 5.08 mm speaker Euroblock selects 70 V or 100 V. Aten gives the minimum load as 80 Ω on a 70 V line and 160 Ω on a 100 V line; both work out at just over 60 W, so keep the total of the speaker taps at or under 60 W. For a 4 Ω stereo pair or adjustable DSP, the Aten AP206 2 x 60 W amplifier with DSP does both.
With Aten’s tap values, one AP106 can run:
Models and taps can be mixed on one line as long as the total stays at 60 W or less: two AS106 on 15 W plus three AS104 on 10 W, for instance. Aten recommends 16 AWG or heavier speaker cable.
A 5-pin 3.5 mm Euroblock takes a balanced or unbalanced line source, stereo or mono, and a 3.5 mm TRS jack takes an unbalanced source; the amplifier sums the left and right of each input to mono. When both carry audio, the AP106 plays the TRS source, so a laptop on the jack takes over from background music on the Euroblock.
The front panel has a volume knob, bass and treble shelving controls with ±6 dB of range, and a signal/clip LED. An 80 Hz high-pass filter at 12 dB per octave is applied to the signal.
The 3-pin RS-232 port (19200 baud, 8N1) is for firmware updates and Aten control systems such as the Aten VK1100A control box; Aten’s compatibility list also names the VK2100A, VK0100, VK0200 and VK224. Its documented commands read the firmware version, event log, output status and temperature, reboot the unit and switch standby on or off.
Besides short-circuit and over- or under-voltage protection on the output, the AP106 guards against overheating: it mutes for one minute and checks again; if still too hot it stays in protection, with the standby LED blinking, until an RS-232 command or a power cycle wakes it.
The sealed, fanless metal case measures 20.00 x 15.72 x 4.40 cm, half the width of a 19-inch rack, and weighs 1.23 kg. Aten says the sealed case allows hidden placement, behind a TV or above a ceiling, though its safety notes still ask that the ventilation openings stay clear. Four foot pads come in the box; mounting kits do not. The accessories Aten lists for it are the Aten 2X-049G rack mounting kit and the 2X-044G under-table kit. It is rated for 0 to 40 °C.
| Rated power | 60 W RMS, 120 W peak |
|---|---|
| Output | 70 V or 100 V (switch), 2-pin 5.08 mm Euroblock |
| Minimum load | 80 Ω at 70 V; 160 Ω at 100 V |
| Frequency response | 80 Hz to 20 kHz, 0/-3 dB at 70 V, 1 W |
| Inputs | 5-pin 3.5 mm Euroblock (bal/unbal); 3.5 mm TRS (unbal, priority) |
| Tone controls | Bass and treble shelf, ±6 dB |
| Control port | RS-232, 3-pin terminal block, 19200 baud |
| Mains | 100 to 240 V, 50/60 Hz, 1 A |
| Case | Half-rack, 20.00 x 15.72 x 4.40 cm, 1.23 kg |
No. An 8 Ω speaker wired straight to the output would sit far below the 80 Ω minimum load. Each speaker needs a line transformer; on the Aten AS104 and AS106 it is built in, so turn their tap selector to a wattage on the 70 V or 100 V scale rather than to 8R.
No. Aten’s command set has no level or tone commands, so volume, bass and treble stay on the front-panel knobs. Where level and EQ have to be set remotely, the AP206 and AP212 are configured over their LAN port instead.
Aten’s method: turn the AP106 to full volume with bass and treble centred, then play pink noise from the source starting at its lowest volume. Raise the source until the signal LED glows solid green, and keep raising it until the LED flashes red. That source setting is the normal input level.
Power Saving Mode turns it off after 30 minutes without input above -50 dBu, and it comes back on once a source reaches -30 dBu. A very quiet background feed can stay below that wake-up level, so raise the source level if the amplifier stays asleep.
| Rated Power | 60Wrms/ 120Wpeak |
|---|---|
| Distortion | THD+N: |
| Frequency Response | 80~20kHz, 0/-3dB @70V, 1W |
| Sensitivity | Balanced: +4dBu Unbalanced: -10dBV (0dBu=0.775Vrms, 0dBV=1Vrms) |
| Amplifier Type | Class D |
| HPF | 80Hz, -12dB/Oct |
| Interfaces | 1 x 5-pin 3.5mm Euroblock (Bal/Unbal Line In) 1 x 3.5mm TRS Unbalanced Phone Jack (Priority) |
|---|---|
| Impedance | Balanced: 20kΩ Unbalanced: 10kΩ |
| Detect Threshold | 50dBu |
| Interfaces | 1 x 2-pin 5.08mm Euroblock |
|---|---|
| Impedance | Minimum Load 70V: 80Ω 100V: 160Ω |
| Audio Effects | 2-band Shelf EQ, +/-6dB |
| Protection | Output Shortcut AMP Output over/under voltage High Frequency Overload Thermal Protect |
| RS-232 | Connector: 3-pin, 3.5mm, Terminal Block Baud rate and protocol: Baud Rate: 19200, Data Bits: 8, Stop Bits:1, Parity: No, Flow Control: No |
|---|
| Power Consumption | 100-240V~, 50/60Hz, 1A |
|---|
| Certification | FCC, CE, UKCA |
|---|
| Operating Temperature | 0~40℃ |
|---|---|
| Humidity | 0-80% RH, Non-Condensing |
| Storage Temperature | 20~60℃ |
| Weight | 1.23 kg ( 2.71 lb ) |
|---|---|
| Housing | Metal |
| Dimensions (L x W x H) | 20.00 x 15.72 x 4.40 cm (7.87 x 6.19 x 1.73 in.) |
| Note | Rack/surface mount kits are sold separately. |
| Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. |